Patchwire CVEs, their patch status, and feeds to follow them

CVE-2020-26272

Fixed in a distro release EPSS 2%CVSS 5.4

The Electron framework lets users write cross-platform desktop applications using JavaScript, HTML and CSS. In versions of Electron IPC prior to 9.4.0, 10.2.0, 11.1.0, and 12.0.0-beta.9, messages sent from the main process to a subframe in the renderer process, through webContents.sendToFrame, event.reply or when using the remote module, can in some cases be delivered to the wrong frame. If your app uses remote, calls webContents.sendToFrame, or calls event.reply in an IPC message handler then it is impacted by this issue. This has been fixed in versions 9.4.0, 10.2.0, 11.1.0, and 12.0.0-beta.9. There are no known workarounds for this issue.

Published 2021-01-28 · CVE record · OSV

Products: electron

Fixed upstream

EcosystemPackageFixed in
npmelectron9.4.0
npmelectron10.2.0
npmelectron11.1.0

Distro releases

ReleasePackageFixed in
Arch Linuxelectron11.1.0-1