Patchwire CVEs, their patch status, and feeds to follow them

CVE-2018-16557

No fix known EPSS <1%CVSS 8.2

A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-2 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-2 DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions < V7.0.3), SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.9), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions < V8.2.1), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). Sending of specially crafted packets to port 102/tcp via Ethernet interface via PROFIBUS or Multi Point Interfaces (MPI) could cause a denial of service condition on affected devices. Flashing with a firmware image may be required to recover the CPU. Successful exploitation requires an attacker to have network access to port 102/tcp via Ethernet interface or to be able to send messages via PROFIBUS or Multi Point Interfaces (MPI) to the device. No user interaction is required. If no access protection is configured, no privileges are required to exploit the security vulnerability. The vulnerability could allow causing a denial of service condition of the core functionality of the CPU, compromising the availability of the system.

Published 2018-12-13 · CVE record · OSV

Products: Siemens SIMATIC S7-400 CPU 412-1 DP V7, Siemens SIMATIC S7-400 CPU 412-2 DP V7, Siemens SIMATIC S7-400 CPU 414-2 DP V7, Siemens SIMATIC S7-400 CPU 414-3 DP V7, Siemens SIMATIC S7-400 CPU 414-3 PN/DP V7, Siemens SIMATIC S7-400 CPU 414F-3 PN/DP V7, Siemens SIMATIC S7-400 CPU 416-2 DP V7, Siemens SIMATIC S7-400 CPU 416-3 DP V7, Siemens SIMATIC S7-400 CPU 416-3 PN/DP V7, Siemens SIMATIC S7-400 CPU 416F-2 DP V7, Siemens SIMATIC S7-400 CPU 416F-3 PN/DP V7, Siemens SIMATIC S7-400 CPU 417-4 DP V7, Siemens SIMATIC S7-400 CPU 412-2 PN V7, Siemens SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants), Siemens SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants), Siemens SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), Siemens SIMATIC S7-410 CPU family (incl. SIPLUS variants), Siemens SIPLUS S7-400 CPU 414-3 PN/DP V7, Siemens SIPLUS S7-400 CPU 416-3 PN/DP V7, Siemens SIPLUS S7-400 CPU 416-3 V7, Siemens SIPLUS S7-400 CPU 417-4 V7